Hitachi is offering three open systems in the UK: the new APERTO 0.4T, the AIRISmate 0.2T, and the 0.3T AIRIS II.


APERTO 0.4T
 

Magnet

The Hitachi APERTO 0.4T system is a new 0.4T permanent magnet system based on a one column support design.

The system has a mass of 10 tonnes. It has VOSI technology: Vertical-field with Optimised Sub-system Integration.

The patient couch is a special feature of this magnet. This is positioned at an angle to the one column system giving a panoramic, 320° open access.

The patient gap is 38 cm. The couch is 70 cm wide and has a side sliding movement with a stroke of 300 mm. Two footswitches located at the lower end of the table allow automatic operation.

 

RF System

The APERTO 0.4T has a 4-channel RF system.

 

Gradients

The gradient system amplitude is 22 mT/m with a slew rate of 55 T/m/s.

 

Applications

Hitachi is showing that APERTO 0.4T is capable of diffusion weighted imaging and single shot EPI.

 

 

AIRIS II 0.3T
 

Magnet

The AIRIS II 0.3T system has a 0.3 tesla permanent, self-shielded magnet.

The main field has a vertical orientation.

The 5 Gauss fringe field is at 195cm in the horizontal plane and 245 cm in the vertical plane.

The system also incorporates a three-axis, per-patient shim.

The patient gap is 43 cm vertically and 110 cm post to post.

The specially designed gantry opening is 210° at the front and 70° at the back.

The patient couch is 80 cm wide and can travel through a vertical distance of 45 cm. It can accommodate patients of up to 227 kg in mass.

The couch also has two-speed, power-driven longitudinal movements. The lateral movement is ±50 cm.

 

Gradients

The gradient system has an amplitude of 15 mT/m with a slew rate of 30T/m/sec.

 

Applications

Hitachi is showing that APERTO 0.4T is capable of diffusion weighted imaging and single shot EPI.

 

 

AIRISmate 0.2T
 

Magnet

The AIRIS MATE has a 0.2 T permanent magnet.

The main field has a vertical orientation.

The specially designed gantry opening is 230° at the front and 70° at the back.

 

RF System

The coils available are:

  • multiple-array head coil
  • head and neck coil
  • multiple-array head and neck coil
  • joint coils (M,L,S)
  • TMJ coil
  • multiple-array wrist coil
  • breast coil
  • multiple-array knee coil
  • QD multiple-array shoulder coil
  • multiple-array flexible body coils (M,S,L)
 

 

Further information can be obtained from Hitachi's website.

 